  Datasheet File OCR Text:
  dc/dc converters thb 6 series, 6 watt features i/o isolation 3000 vacrms rated for 300 vrms working voltage medical safety to ul 60601-1 and iec/en 60601-1 3rd edition, 2 x moop industrial safety to iec/en/ul 60950-1 ultra compact dip-24 package wide 2:1 input voltage ranges operating temperature range C40c to +71c low leakage current short circuit protection input flter to meet en 55022, class a 3-year product warranty the thb 6 series is a new range of high performance, regulated dc/dc converters in a dip-24 plastic package. a reinforced i/o-isolation system and a wide 2:1 input voltage range make this product the best choice for many demanding applications like transportation systems, industrial controls, medical equipment, instrumentation, everywhere where high basic-, supplementary- or reinforced insulation is required to meet requested safety standards. a high effciency allows safe operation in a temperature range of C40c to +71c. other features of this product are over voltage protection and internal emi-input flter to meet en 55022 class a without additional components. full smd-design with exclusive use of ceramic capacitors ensures a very high reliability and a long product lifetime. order code input voltage range output voltage output current max. effciency typ. thb 6-1211 5 vdc 1000 ma 75 % thb 6-1212 9 - 18 vdc 12 vdc 500 ma 78 % thb 6-1222 (12 vdc nominal) 12 vdc 250 ma 78 % thb 6-1223 15 vdc 200 ma 78 % thb 6-2411 5 vdc 1000 ma 77 % thb 6-2412 18 - 36 vdc 12 vdc 500 ma 80 % thb 6-2422 (24 vdc nominal) 12 vdc 250 ma 80 % thb 6-2423 15 vdc 200 ma 80 % thb 6-4811 5 vdc 1000 ma 77 % thb 6-4812 36 - 75 vdc 12 vdc 500 ma 80 % thb 6-4822 (48 vdc nominal) 12 vdc 250 ma 80 % thb 6-4823 15 vdc 200 ma 80 % models page 1 of 3 c b scheme u l 60950 -1 ul 60601-1 u l 60950 -1 iec 60950 -1 iec 60601-1 http://www.tracopower.com
dc/dc converters thb 6 series 6 watt all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. page 2 of 3 input specifications input current at no load / full load 12 vin; 5 vdc model: 30 ma typ. / 570 ma typ. 12 vin; other models: 30 ma typ. / 640 ma typ. 24 vin; 5 vdc model: 20 ma typ. / 280 ma typ. 24 vin; other models: 20 ma typ. / 315 ma typ. 48 vin; 5 vdc model: 10 ma typ. / 140 ma typ. 48 vin; other models: 10 ma typ. / 155 ma typ. start-up voltage / 12 vin models: 9 vdc / 8.5 vdc typ. under voltage shut down 24 vin models: 18 vdc / 16 vdc typ. 48 vin models: 36 vdc / 34 vdc typ. recommended external input fuse (slow blow) 12 vin models: 1.2 a 24 vin models: 0.6 a 48 vin models: 0.3 a surge voltage (1 sec. max.) 12 vin models: 25 vdc max. 24 vin models: 50 vdc max. 48 vin models: 100 vdc max. input filter en 55022 class a output specifications voltage set accuracy 1.0 % regulation C input variation vin min. to vin max. 1.0 % max. C load variation 25 C 100 %: single output models: 1.0 % max. dual output models: 2.0 % max. balanced load minimum load 20 % of rated max. output current. (operation at lower load is safe but major deviations to specified data may occur) ripple and noise (20 mhz bandwidth) 5 vdc models: 100 mvp-p max. other models: 150 mvp-p max. transient response (25% load step change) 500 s max. current limitation >120 % iout max. short circuit protection indefinite (automatic recovery) capacitive load 5 vdc output models: 1000 f max. 12 vdc output models: 470 f max. dual output models: 220 f max. (each output) isolation / safety standards isolation test voltage (flash tested 1 sec.) 6000 vpk i/o isolation voltage C according iec/en 60601-1 3000 vacrms, rated for 300 vrms working (50hz, 60sec.) voltage, 2 x moop C according iec/en 60950-1 4800 vacrms, rated for 300 vrms working voltage leakage current (at 240vac, 60hz) 2 a i/o isolation capacity (at 100khz, 1v) 7 pf typ. i/o isolation resistance (at 500vdc) >1000 mohm safety standards iec 60950-1:2005 (2nd ed.) +a1:2009 and/or en 60950-1:2006 +a1:2010 +a11:2009 +12 :2011, u l 60950 -1 csa c22.2 no. 60950-1-03 iec/en 60601-1 3rd edition, 2 x moop, ul 60601-1, csa c22.2 no. 601.1 safety approvals C cb test certificate according iec 60950-1 www.tracopower.com/products/thb6-cb60950.pdf C cb test certificate according iec 60601-1(3rd edition) www.tracopower.com/products/thb6-cb60601.pdf C csa certificate according ul 60950-1/60601-1 www.tracopower.com/products/thb6-csa.pdf C ul certificate to ul 60950-1 file e188913 cond.: reinforced insulation rated for 55c max. with power de-rating 3%/k above 45c ambient. file copy : e188913qqgq2.pdf http://www.tracopower.com
page 3 of 3 dc/dc converters thb 6 series 6 watt outline dimensions rev. .may 06, 2013 pin single dual 1 +vin (vcc) +vin (vcc) 11 no pin common 12 Cvout no pin 13 +vout Cvout 15 no pin +vout 23 Cvin (gnd) Cvin (gnd) 24 Cvin (gnd) Cvin (gnd) pin-out dimensions in [mm], () = inch pin diameter ? 0.6 0.05 (0.024 0.002) tolerances 0.25 (0.01) pin pich tolerances 0.13 (0.005) general specifications temperature ranges C operating C40c to +71c C case +95c max. C storage C40c to +125c derating 3.0 %/k above 60c humidity (non condensing) 95 % rel h max. temperature coefficient 0.02 %/k typ. reliability, calculated mtbf ( m i l- h d b k-217 f at 25c, ground benign ) >700000 h switching frequency 150 khz typ. (puls width modulation) altitude during operation up to 5000 m (16400 ft) approved environmental compliance C reach www.tracopower.com/products/thb6-reach.pdf C rohs rohs directive 2011/65/eu physical specifications casing material non conductive plastic (ul 94v-0-rated) potting material silicon tse 3331 (ul 94v-0-rated) weight 18 g (0.63 oz) soldering temperature max. 265c / 10 sec. 31.8 2x2.54 20.32 2.54 2.0 0.5 12.0 3.8 (1.25) (0.8) (0.1) (2x0.1) (0.08) (0.47) (0.15) (0.02) 2.54 20.3 15.2 (0.8) (0.6) (0.1) bottom view 11 1 12 13 15 23 24 - the component is not be used in an oxygen rich environment. - the component is not to be used in conjunction with fammable anaesthetics and agents. - the component has to be disposed appropriately. please refer to local regulations (waste electrical and electronic equipment). - a modifcation of the component is not allowed. application note : www.tracopower.com/products/thb6 -appl ication.pdf sp ec i?cati ons can be changed wi thout noti ce! make sure you are using the latest documentation, downloadable at www.tracopower. com www .tracopower. com


▲Up To Search▲   

 
Price & Availability of THB62411

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X